APC PowerChute Network Shutdown shuts Hyper-V hosts down in an orderly way, but requires an APC network card and, since version 5, is licensed per virtualization node on a subscription. Licensing, UPS lock-in and Hyper-V integration in a factual comparison.
Two PowerChute products, two jobs
Anyone buying an APC UPS meets the PowerChute name twice. The two programs differ in connection, reach and licensing:
- PowerChute Business Edition — for Smart-UPS models connected directly to a server by USB or serial cable. The agent runs on that server and shuts it down. Free, no network card needed, but limited to the directly attached machine. Schneider Electric is replacing Business Edition with PowerChute Serial Shutdown.
- PowerChute Network Shutdown (PCNS) — talks to the UPS Network Management Card over the network and can therefore serve several servers on one UPS. The "for Virtualization and HCI" edition supports VMware vSphere, Hyper-V and System Center Virtual Machine Manager (SCVMM), including orderly VM and cluster shutdown and startup.
For Hyper-V hosts with an orderly shutdown, PCNS is the relevant APC product, and it is the one this comparison is about. Two points decide it in practice: the licensing model and the tie to APC hardware.
One license per Hyper-V host, with a term
For physical Windows or Linux servers without a hypervisor, PCNS can be used without a subscription according to Schneider Electric. That edition also runs on a Hyper-V host, but only as a host shutdown: the host is shut down like a Windows server and the VMs are left to Hyper-V's automatic stop action. VM shutdown, VM migration, VM prioritisation and shutting down whole clusters require the "for Virtualization and HCI" edition: it is licensed per virtualization node as a subscription with a term of 1, 3, 5 or 6 years. For Hyper-V that means one license per standalone Hyper-V host; in a failover cluster every node counts. Each PowerChute agent needs its own activation ID, and adding nodes means amending the subscription.
| Environment | PCNS licenses |
|---|---|
| 1 UPS, 1 Hyper-V host | 1 |
| 1 UPS, 3 standalone Hyper-V hosts | 3 |
| 2 UPS units, 2-node failover cluster, 1 standalone host | 3 |
Then there is the hardware: PCNS requires a Network Management Card in every UPS. With a subscription the license cost comes back with every term, and every additional host raises it. The UPS Hyper-V Shutdown Monitor is licensed once, €199 (Standard) to €499 (Enterprise), for any number of Hyper-V hosts; see editions & pricing.
Vendor information as of October 2026, according to the product page "PowerChute Network 6-Year Subscription" (se.com; 1, 3 and 5 years also exist), Schneider Electric's knowledge-base article "Activate PowerChute Network Shutdown License" (license per node, per standalone Hyper-V host, one activation ID per agent) and the SFPCNS product page (subscription and Network Management Card required; no subscription for Windows and Linux servers). Terms may change; Schneider Electric or your reseller can quote current prices.
APC only, or open protocols
PCNS talks exclusively to the Network Management Card of an APC UPS. If the same infrastructure also contains an Eaton, CyberPower or Vertiv unit, through an acquisition, a site takeover or simply growth over the years, that unit needs a second tool with its own configuration, its own interface and its own updates. Or it stays unmonitored.
The UPS Hyper-V Shutdown Monitor reads UPS units over SNMP v1/v2c/v3 and NUT (Network UPS Tools), both in every edition:
- Natively via SNMP — APC (PowerNet MIB), Eaton (XUPS and MGE), Socomec NetVision 5 and 7, Vertiv/Liebert, Huawei and CyberPower with their vendor-specific OIDs, SNMPv3 with SHA and AES included.
- Everything else — through the standard MIB under RFC 1628 (UPS-MIB), which most network cards offer in addition, or through a NUT server, which covers over 100 vendors (according to the NUT compatibility list). The guide NUT on Windows shows what that looks like on Windows.
- Several UPS units in one installation (from Pro) — each UPS with its own thresholds, each host assigned to a specific UPS. If one UPS fails, only its hosts shut down. Three-phase UPS units report their readings per phase L1 to L3 (Pro).
- UPS alarms in view — active alarms from the UPS alarm table (RFC 1628, Eaton, Socomec and NUT) and the bypass state appear on the dashboard, in every edition.
For environments with several UPS brands, the guide Monitoring UPS units from several vendors is the place to start.
PowerChute Network Shutdown and UPS Hyper-V Shutdown Monitor compared
| Criterion | PowerChute Network Shutdown 5 | UPS Hyper-V Shutdown Monitor |
|---|---|---|
| License | subscription per virtualization node, 1, 3, 5 or 6 years | one-time license, €199 to €499 |
| More Hyper-V hosts | one license per standalone host or cluster node | unlimited in every edition |
| UPS vendors | APC only, with Network Management Card | APC, Eaton, Socomec, Vertiv, Huawei, CyberPower natively; others via RFC 1628 and NUT |
| Several UPS units, hosts assigned per UPS | configuration per PowerChute agent | from Pro, in one installation |
| Shutting down VMs | VM and cluster shutdown in the licensed edition | shut down or save (Save-VM) per VM, order and timeouts, every edition |
| Live migration instead of shutdown | — | from Pro |
| Agent on the hosts | PowerChute agent per host or management system | agentless, WinRM with Negotiate, HTTPS optional |
| Alerting | email, SNMP trap; Microsoft 365, Teams, SMS and webhook from Pro | |
| Monitoring integration | — | /health, Prometheus and PRTG (Enterprise) |
| Reports | — | availability, energy, SLA per host, monthly report by email (Pro) |
| Deployment | Windows service with the agent's web interface | desktop app and Windows service; remote web interface in Enterprise |
| Other hypervisors | VMware vSphere, SCVMM, HCI platforms | Hyper-V and other Windows servers only |
"—" means: not listed as a feature in the vendor documentation (as of October 2026). What the UPS Hyper-V Shutdown Monitor includes in which edition is on the Features page.
When PowerChute is the right choice
PowerChute is strong where the environment matches what it was built for:
- One physical server on a Smart-UPS — by USB or serial cable, Business Edition or Serial Shutdown is enough, with no network card and no license.
- Physical Windows or Linux servers without a hypervisor — here PCNS can be used without a license according to Schneider Electric.
- VMware environments — vSphere and vCenter are PCNS's core territory. The UPS Hyper-V Shutdown Monitor controls Hyper-V and Windows servers only.
- HCI and mixed virtualization — if VMware or an HCI platform must be protected alongside Hyper-V, PCNS covers that in one product.
- An existing Schneider Electric ecosystem — if APC UPS units, network cards, subscriptions and support already run under one framework agreement.
For a pure Hyper-V environment with several hosts, possibly with UPS units from different vendors, PCNS makes you pay for every host and every term again. The same reasoning for Eaton is in the guide Eaton IPM alternative for Hyper-V.
Checklist for the decision
- How many Hyper-V hosts add up? Standalone hosts and cluster nodes each count under PCNS, and for every term of the subscription.
- Is more than one UPS brand on the network? Then PCNS means a second tool or unmonitored UPS units. SNMP under RFC 1628 and NUT know no brand boundary.
- Does every UPS have a Network Management Card? No card, no PCNS. For the UPS Hyper-V Shutdown Monitor a NUT server, for example on a NAS, works as an alternative.
- Should hosts on different UPS units be coordinated? Then the host-to-UPS assignment matters, and with two sites the live migration to the partner host (both from Pro). More in the guide Hyper-V failover cluster during a power outage.
- Do you need VMware or HCI? If yes, much speaks for PCNS. If no, a tool specialised in Hyper-V is enough.
Frequently asked questions
Is PowerChute Network Shutdown free?
For physical Windows or Linux servers without a hypervisor, yes, according to Schneider Electric. On a Hyper-V host as well, but only as a host shutdown without VM functions. VM shutdown, VM migration and shutting down whole clusters are only available in the “for Virtualization and HCI” edition, licensed per virtualization node as a subscription with a term of 1, 3, 5 or 6 years. A trial license enables all functions for 30 days and can be activated once. Vendor information as of October 2026.
How many PowerChute licenses do I need for Hyper-V?
One per standalone Hyper-V host; in a failover cluster one per node. Each PowerChute agent needs its own activation ID. Three standalone hosts therefore mean three licenses, again at every renewal.
Does PowerChute work with UPS units from other vendors?
No. PowerChute Network Shutdown requires the Network Management Card of an APC UPS. The UPS Hyper-V Shutdown Monitor reads APC, Eaton, Socomec, Vertiv, Huawei and CyberPower natively via SNMP, and all others via RFC 1628 or NUT.
Can I run PowerChute and the UPS Hyper-V Shutdown Monitor side by side?
Yes. Both only read from the network card, PCNS through its agent, the UPS Hyper-V Shutdown Monitor via SNMP. Only one tool should shut down the same hosts, though. Configure the other without hosts, or use it for monitoring only, for example with the "monitoring only" mode of the Enterprise edition.
More guides
UPS alerts via Microsoft 365 and Teams
Graph instead of SMTP AUTH, Workflows instead of connectors.
UPS shutdown via PowerShell script
Ten weak spots that only show up in a real outage.
CyberPower and Riello for Hyper-V
PowerPanel Business and PowerShield³ compared.
Replacing UPS batteries
Ageing, warning signs and swapping without a protection gap.
Restarting after a power outage
Starting servers, storage and VMs automatically when power returns.
Eaton IPM alternative for Hyper-V
Node licensing, editions and Hyper-V integration compared.
Hyper-V on Server Core
Protect hosts without a desktop via WinRM or a web interface.
SNMPv3 on a UPS network card
authPriv with SHA and AES instead of a plain-text community.
NUT on Windows
Query a UPS via Network UPS Tools from a NAS or Linux server.
Shutting down Hyper-V VMs in a power outage
Stop action, shutdown order and time budget for an orderly shutdown.
Hyper-V Failover Cluster Power Outage
Securing quorum, Cluster Shared Volumes and live migration.
Active Directory & Power Outages
The USN rollback myth and the real risks for domain controllers.
SQL Server & Exchange on Hyper-V
Protecting databases during a power outage.
Calculating UPS Runtime Correctly
Why the datasheet runtime rarely holds.
Monitoring UPS Units From Multiple Vendors
One tool instead of several silos.
UPS Monitoring (Enterprise)
Monitoring-only mode, warning thresholds and UPS self-test.
Try vendor-independent UPS monitoring
Free for 30 days, all features included — SNMP and NUT supported equally, unlimited Hyper-V hosts.