Skip to content
UPSmonitor 247-IT

247-IT Guide

PowerChute Alternative for Hyper-V

APC PowerChute Network Shutdown shuts Hyper-V hosts down in an orderly way, but requires an APC network card and, since version 5, is licensed per virtualization node on a subscription. Licensing, UPS lock-in and Hyper-V integration in a factual comparison.

01 Starting point The PowerChute name covers two products with different purposes.

Two PowerChute products, two jobs

Anyone buying an APC UPS meets the PowerChute name twice. The two programs differ in connection, reach and licensing:

  1. PowerChute Business Edition — for Smart-UPS models connected directly to a server by USB or serial cable. The agent runs on that server and shuts it down. Free, no network card needed, but limited to the directly attached machine. Schneider Electric is replacing Business Edition with PowerChute Serial Shutdown.
  2. PowerChute Network Shutdown (PCNS) — talks to the UPS Network Management Card over the network and can therefore serve several servers on one UPS. The "for Virtualization and HCI" edition supports VMware vSphere, Hyper-V and System Center Virtual Machine Manager (SCVMM), including orderly VM and cluster shutdown and startup.

For Hyper-V hosts with an orderly shutdown, PCNS is the relevant APC product, and it is the one this comparison is about. Two points decide it in practice: the licensing model and the tie to APC hardware.

02 Licensing Since PCNS 5 every virtualization node counts, and it is a subscription.

One license per Hyper-V host, with a term

For physical Windows or Linux servers without a hypervisor, PCNS can be used without a subscription according to Schneider Electric. That edition also runs on a Hyper-V host, but only as a host shutdown: the host is shut down like a Windows server and the VMs are left to Hyper-V's automatic stop action. VM shutdown, VM migration, VM prioritisation and shutting down whole clusters require the "for Virtualization and HCI" edition: it is licensed per virtualization node as a subscription with a term of 1, 3, 5 or 6 years. For Hyper-V that means one license per standalone Hyper-V host; in a failover cluster every node counts. Each PowerChute agent needs its own activation ID, and adding nodes means amending the subscription.

Example: PCNS licenses under the node count
Environment PCNS licenses
1 UPS, 1 Hyper-V host1
1 UPS, 3 standalone Hyper-V hosts3
2 UPS units, 2-node failover cluster, 1 standalone host3

Then there is the hardware: PCNS requires a Network Management Card in every UPS. With a subscription the license cost comes back with every term, and every additional host raises it. The UPS Hyper-V Shutdown Monitor is licensed once, €199 (Standard) to €499 (Enterprise), for any number of Hyper-V hosts; see editions & pricing.

Vendor information as of October 2026, according to the product page "PowerChute Network 6-Year Subscription" (se.com; 1, 3 and 5 years also exist), Schneider Electric's knowledge-base article "Activate PowerChute Network Shutdown License" (license per node, per standalone Hyper-V host, one activation ID per agent) and the SFPCNS product page (subscription and Network Management Card required; no subscription for Windows and Linux servers). Terms may change; Schneider Electric or your reseller can quote current prices.

03 UPS lock-in PCNS knows only APC. Open protocols do not know the vendor.

APC only, or open protocols

PCNS talks exclusively to the Network Management Card of an APC UPS. If the same infrastructure also contains an Eaton, CyberPower or Vertiv unit, through an acquisition, a site takeover or simply growth over the years, that unit needs a second tool with its own configuration, its own interface and its own updates. Or it stays unmonitored.

The UPS Hyper-V Shutdown Monitor reads UPS units over SNMP v1/v2c/v3 and NUT (Network UPS Tools), both in every edition:

  1. Natively via SNMP — APC (PowerNet MIB), Eaton (XUPS and MGE), Socomec NetVision 5 and 7, Vertiv/Liebert, Huawei and CyberPower with their vendor-specific OIDs, SNMPv3 with SHA and AES included.
  2. Everything else — through the standard MIB under RFC 1628 (UPS-MIB), which most network cards offer in addition, or through a NUT server, which covers over 100 vendors (according to the NUT compatibility list). The guide NUT on Windows shows what that looks like on Windows.
  3. Several UPS units in one installation (from Pro) — each UPS with its own thresholds, each host assigned to a specific UPS. If one UPS fails, only its hosts shut down. Three-phase UPS units report their readings per phase L1 to L3 (Pro).
  4. UPS alarms in view — active alarms from the UPS alarm table (RFC 1628, Eaton, Socomec and NUT) and the bypass state appear on the dashboard, in every edition.

For environments with several UPS brands, the guide Monitoring UPS units from several vendors is the place to start.

04 Comparison The points that decide it in Hyper-V environments.

PowerChute Network Shutdown and UPS Hyper-V Shutdown Monitor compared

Comparison for Hyper-V environments
Criterion PowerChute Network Shutdown 5 UPS Hyper-V Shutdown Monitor
Licensesubscription per virtualization node, 1, 3, 5 or 6 yearsone-time license, €199 to €499
More Hyper-V hostsone license per standalone host or cluster nodeunlimited in every edition
UPS vendorsAPC only, with Network Management CardAPC, Eaton, Socomec, Vertiv, Huawei, CyberPower natively; others via RFC 1628 and NUT
Several UPS units, hosts assigned per UPSconfiguration per PowerChute agentfrom Pro, in one installation
Shutting down VMsVM and cluster shutdown in the licensed editionshut down or save (Save-VM) per VM, order and timeouts, every edition
Live migration instead of shutdown—from Pro
Agent on the hostsPowerChute agent per host or management systemagentless, WinRM with Negotiate, HTTPS optional
Alertingemailemail, SNMP trap; Microsoft 365, Teams, SMS and webhook from Pro
Monitoring integration—/health, Prometheus and PRTG (Enterprise)
Reports—availability, energy, SLA per host, monthly report by email (Pro)
DeploymentWindows service with the agent's web interfacedesktop app and Windows service; remote web interface in Enterprise
Other hypervisorsVMware vSphere, SCVMM, HCI platformsHyper-V and other Windows servers only

"—" means: not listed as a feature in the vendor documentation (as of October 2026). What the UPS Hyper-V Shutdown Monitor includes in which edition is on the Features page.

05 Being fair For some environments PowerChute is the better choice.

When PowerChute is the right choice

PowerChute is strong where the environment matches what it was built for:

  1. One physical server on a Smart-UPS — by USB or serial cable, Business Edition or Serial Shutdown is enough, with no network card and no license.
  2. Physical Windows or Linux servers without a hypervisor — here PCNS can be used without a license according to Schneider Electric.
  3. VMware environments — vSphere and vCenter are PCNS's core territory. The UPS Hyper-V Shutdown Monitor controls Hyper-V and Windows servers only.
  4. HCI and mixed virtualization — if VMware or an HCI platform must be protected alongside Hyper-V, PCNS covers that in one product.
  5. An existing Schneider Electric ecosystem — if APC UPS units, network cards, subscriptions and support already run under one framework agreement.

For a pure Hyper-V environment with several hosts, possibly with UPS units from different vendors, PCNS makes you pay for every host and every term again. The same reasoning for Eaton is in the guide Eaton IPM alternative for Hyper-V.

06 Checklist Five questions that usually settle it.

Checklist for the decision

  1. How many Hyper-V hosts add up? Standalone hosts and cluster nodes each count under PCNS, and for every term of the subscription.
  2. Is more than one UPS brand on the network? Then PCNS means a second tool or unmonitored UPS units. SNMP under RFC 1628 and NUT know no brand boundary.
  3. Does every UPS have a Network Management Card? No card, no PCNS. For the UPS Hyper-V Shutdown Monitor a NUT server, for example on a NAS, works as an alternative.
  4. Should hosts on different UPS units be coordinated? Then the host-to-UPS assignment matters, and with two sites the live migration to the partner host (both from Pro). More in the guide Hyper-V failover cluster during a power outage.
  5. Do you need VMware or HCI? If yes, much speaks for PCNS. If no, a tool specialised in Hyper-V is enough.
07 Questions Short answers to common questions.

Frequently asked questions

Is PowerChute Network Shutdown free?

For physical Windows or Linux servers without a hypervisor, yes, according to Schneider Electric. On a Hyper-V host as well, but only as a host shutdown without VM functions. VM shutdown, VM migration and shutting down whole clusters are only available in the “for Virtualization and HCI” edition, licensed per virtualization node as a subscription with a term of 1, 3, 5 or 6 years. A trial license enables all functions for 30 days and can be activated once. Vendor information as of October 2026.

How many PowerChute licenses do I need for Hyper-V?

One per standalone Hyper-V host; in a failover cluster one per node. Each PowerChute agent needs its own activation ID. Three standalone hosts therefore mean three licenses, again at every renewal.

Does PowerChute work with UPS units from other vendors?

No. PowerChute Network Shutdown requires the Network Management Card of an APC UPS. The UPS Hyper-V Shutdown Monitor reads APC, Eaton, Socomec, Vertiv, Huawei and CyberPower natively via SNMP, and all others via RFC 1628 or NUT.

Can I run PowerChute and the UPS Hyper-V Shutdown Monitor side by side?

Yes. Both only read from the network card, PCNS through its agent, the UPS Hyper-V Shutdown Monitor via SNMP. Only one tool should shut down the same hosts, though. Configure the other without hosts, or use it for monitoring only, for example with the "monitoring only" mode of the Enterprise edition.

Try vendor-independent UPS monitoring

Free for 30 days, all features included — SNMP and NUT supported equally, unlimited Hyper-V hosts.